@cappern/node-red-netflow 0.0.5

Node-RED node that decodes NetFlow data.

npm install @cappern/node-red-netflow

node-red-netflow

A Node-RED node that decodes NetFlow data received as a Buffer from a UDP-in node using the node-netflowv9 library. The decoded output is a structured JavaScript object containing a header and an array of flow records.

Overview

The node-red-netflow node processes NetFlow packets (commonly version 9) by converting the binary data into a JavaScript object. This object includes detailed metadata about the packet (under the "header" property) and an array of decoded flow records (under the "flows" property).

Features

  • Easy Integration: Simply connect a UDP-in node configured to output binary data as a Buffer.
  • Structured Output: Decoded output includes a "header" object and a "flows" array.
  • Detailed Flow Records: Each flow record contains source/destination IP addresses, ports, protocol information, packet and byte counts, and timing information.

Installation

To install this node, either use the Node palette or run the following command in your Node-RED user directory:

    npm install @cappern/node-red-netflow

After installation, restart Node-RED to load the new node.

Usage

  1. Configure a UDP-in Node: Set up a UDP-in node in your flow to receive NetFlow data. Ensure it outputs data as a binary Buffer.
  2. Connect the node-red-netflow Node: Wire the output of the UDP-in node to the node-red-netflow node.
  3. Deploy Your Flow: Once deployed, the node will decode the incoming NetFlow packet and output a JavaScript object.

Decoded Object Structure

The output object consists of the following properties:

Header

An object containing metadata about the NetFlow packet:

  • version: NetFlow version (e.g., 9)
  • count: Number of flow records in the packet
  • uptime: Uptime of the exporting device
  • seconds: UNIX timestamp (seconds since 1970) when the packet was sent
  • sequence: Sequence number of the packet
  • sourceId: Source identifier (typically set by the exporting device)

Flows

An array of decoded flow records. Each record includes properties such as:

  • ipv4_src_addr: Source IPv4 address
  • ipv4_dst_addr: Destination IPv4 address
  • l4_src_port: Layer 4 source port
  • l4_dst_port: Layer 4 destination port
  • in_bytes: Number of bytes transferred
  • in_pkts: Number of packets transferred
  • protocol: IP protocol (e.g., 6 for TCP, 17 for UDP)
  • input_snmp and output_snmp: SNMP interface indices
  • first_switched: Timestamp when the flow started
  • last_switched: Timestamp when the flow ended
  • fsId: FlowSet ID

Example Output

Here is an example of what the decoded object might look like:

{
  "header": {
    "version": 9,
    "count": 28,
    "uptime": 1348093000,
    "seconds": 1740245416,
    "sequence": 2875,
    "sourceId": 0
  },
  "flows": [
    {
      "ipv4_src_addr": "192.168.1.2",
      "ipv4_dst_addr": "192.168.99.12",
      "l4_src_port": 46532,
      "l4_dst_port": 6053,
      "in_bytes": 200,
      "in_pkts": 5,
      "protocol": 6,
      "input_snmp": 10,
      "output_snmp": 10,
      "first_switched": 1347790812,
      "last_switched": 1347793632,
      "fsId": 5206
    }
  ]
}

References

License

This project is licensed under the MIT License. See the LICENSE file for details.

Contributing

Contributions are welcome! Please submit any issues or pull requests via GitHub.

Node Info

Version: 0.0.5
Updated 2 months, 3 weeks ago
License: MIT
Rating: not yet rated

Categories

Actions

Rate:

Downloads

8 in the last week

Nodes

  • netflow

Keywords

  • node-red
  • netflow
  • node-netflowv9
  • udp
  • network

Maintainers